FDA Recall D-0277-2024

Denver Solutions, LLC DBA Leiters Health · Englewood, CO

Class I — life-threatening Ongoing 868 days on record

Highest impact — Class I recall — FDA determination of strong likelihood of serious adverse health consequence or death. Distribution is nationwide and the recall remains in progress.

Product

FentaNYL citrate PF, 1000 mcg per 100 mL 0.9% Sodium Chloride (10 mcg per mL), Item F3355, for IV use only; Leiters 13796 Compark Blvd Englewood, CO 80112; NDC 71449-072-41.

Lot / code: Lot #: 2331062, Exp. Date: 02/08/2024; 2331224, Exp. Date 03/18/2024; 2331270, Exp. Date 03/28/2024.

Quantity: 8,976 IV bags

Reason for recall

Superpotent Drug: semi-automated IV bag filling system can malfunction and provide a double dose of drug product to IV bags.

Recall record

Recall number
D-0277-2024
Classification
Class I
Status
Ongoing
Voluntary or mandated
Voluntary: Firm initiated
Firm notification
E-Mail
Distribution
Nationwide within the United States
Recall initiated
2023-12-28
Classified by FDA Center
2024-01-29
FDA published
2024-02-07
Recalling firm
Denver Solutions, LLC DBA Leiters Health
Firm location
Englewood, CO

Operational response

A Class I recall indicates a strong likelihood of serious adverse health consequence or death. Pull affected lots from active dispensing immediately. Segregate inventory in a marked, locked location pending destruction or return. If product has already been dispensed, identify affected patients and contact them by your standard recall-notification protocol.